Rezeption

Sie wurden nach Ihrer Lehrausbildung bei einer kleinen und preisbewussten Elektrofirma angestellt. Nachdem Ihr Chef erfahren hat, dass Sie regelmäßig englische Fachzeitschriften lesen, bittet er Sie die 3 Werbeblätter auszuwerten und ihm zu erklären, welches Sie für das beste halten. Anschließend sichten Sie das Handbuch, betrachten das Experiment und beantworten die Fragen.

MM34 GENERAL PURPOSE MULTIMETER MM34 £24.80

3½ digit LCD display with automatic polarity indication and automatic zero.
DC VOLTS Ranges: 1mV to 600V (4 ranges)
AC VOLTS Ranges: 100mV to 600V (2 ranges) (50Hz to 500Hz)
DC CURRENT Ranges: 0.1µA - 10A (5 ranges)
RESISTANCE Ranges: 10M ohms to 20M ohms (5 ranges)
DIODE TEST
BATTERY TEST Range:1.5V (110mA), 9V (9mA)
Dimensions: 143 x 68 x 47mm.
Includes: test leads, battery and user manual.

 

MM35 AUTORANGING MULTIMETER MM35 (£34.75)

3½ digit LCD display with function indicator and automatic polarity and zero
DC VOLTS Ranges: 100µV to 600V (5 ranges)
AC VOLTS Ranges: 100µV to 600V (5 ranges) (50Hz to 200Hz <32V & 50 to 60Hz >32V)
DC CURRENT Ranges: 0.1µA - 10A (6 ranges)
AC CURRENT Ranges: 0.1µA - 10A (6 ranges) (50Hz to 20Hz)
RESISTANCE Ranges: 100m ohms to 30M ohms (6 ranges). Continuity buzz at <20 ohms
DIODE TEST
Reading hold button
Autoranging with range hold and manual range change.
Auto power down after 10 mins
Dimensions: 143 x 68 x 47mm.
Includes: test leads, battery and user manual.

 

MM37 SAFETY SENSING MULTIMETER MM37 £39.60

3½ digit LCD display with automatic polarity and zero.
DC VOLTS Ranges: 60µV to 600V (4 ranges)
AC VOLTS Ranges: 100µV to 600V (4 ranges) (50Hz to 500Hz)
DC CURRENT Ranges: 0.1µA to 10A (4 ranges)
AC CURRENT Ranges: 0.1µA to 10A (4 ranges) (50Hz to 500Hz)
RESISTANCE Ranges: 100m ohms to 20M ohms (6 ranges). Continuity buzz at <100 ohms
Diode Test
Voltage Indicator (audible & visual): with the test leads removed this operates in any function or range position. No actual physical contact is required, just close proximity.
Battery Test: 1.5V & 9V
Dimensions: 143 x 68 x 47mm.
Includes: test leads, battery and user manual. l

http://www.martindale-electric.co.uk/multimeters/index.htm

 

2. Manual

How to measure voltage
WARNING Never apply more than 600V AC/DC at input terminals. Exceeding these threshold values could lead to the instrument being damaged or personnel injuries.
WARNING Disconnect test probes from the multimeter prior to selecting a different measurement range.

How to measure resistance
WARNING Prior to any measurement ensure that the multimeter is not live. If required, carry out voltage measurement for verification.

For measuring values of circuit components, the multimeter must be active and produce its own voltages and/or currents. For example, one way to find the resistance of an element is to drive a small current through it and an internal reference resistor and then measure the voltage drop across the reference resistor.
When measuring a resistance, the resistor must not be connected to a circuit. If the resistor is connected to a circuit, the multimeter would actually be measuring the apparent resistance between the two probes. This would not only include the resistor, but the rest of the circuit as well.

Environmental concerns for the multimeter MM37
The environmental concerns for all multimeters are primarily temperature, humidity, shock, and vibration.
The operating temperature range is limited by the liquid crystal display. At low temperatures it becomes sluggish and hard to read. At high temperatures contrast may degrade due to the change in optimum LCD operating voltage with temperature.

Exceeding the non-operating temperature range may result in permanent deformation of the LCD polarizer, particularly when combined with high humidity.

After changing the temperature of the multimeter MM37 significantly, 30 minutes should be allowed for it to stabilize to the new ambient temperature before making important readings.

The specified accuracy is valid only for 23 ±5° C and less than 70 or 80% relative humidity. The instrument is certainly usable over a much wider range but its accuracy will be degraded to some degree.

The multimeter MM37 is relatively well protected against humidity; however, it is not hermetically sealed and excessive humidity may cause internal condensation and possible loss of accuracy.

Shock and vibration are very important for the multimeter MM37. It is designed to survive a 1 metre drop onto a hard surface.

 

3. Experiment

Connect a 1 M? resistor to +5 V output of the power supply. Measure the voltage on either side of the resistor (points 1 and 2) with the multimeter. Assuming that the voltmeter is a resistor in series with the 1 M??resistor, calculate the resistance of the meter. Repeat the measurements with a 100 k? and a 10 M??resistors to test the accuracy of the range selection.
 

 

Fragen

Werbung

1. Vergleichen Sie die 3 Multimeter und entscheiden Sie, welches das beste für Ihre Firma wäre. Nennen Sie mindestens 5 Argumente.

 

Manual

2. Was muss bei der Spannungsmessung beachtet werden? Nennen Sie auch die Begründung, wenn sie angegeben wurde.
3. Was sagt der Warnhinweis der Widerstandsmessung aus?
4. Wie funktioniert die Widerstandsmessung?
5. Woran muß man bei der Widerstandsmessung denken? Warum?
6. Welche Umweltfaktoren sind für das Meßgerät MM37 besonders wichtig? Geben Sie auch die Grenzwerte der einzelnen Faktoren an.
7. Wie kann die Anzeige des Multimeters beschädigt werden?
8. Was muß man berücksichtigen, wenn man in kühlen Räumen mißt?
 

Experiment

9. Wie ist das Experiment aufgebaut und was soll untersucht werden?
 

 

Textproduktion

Ihr Chef ist vom analogen MULTIMETER MM37 begeistert. Nehmen Sie mit der Firma "Martindale Electric" Kontakt auf und bestellen Sie 10 Exemplare. Erkundigen Sie sich dabei nach

- Preisliste
- Mengenrabatt
- Zahlungsmodalitäten
- Lieferfristen

Die Adresse hat Ihnen das Employmentservice übermittelt:

Martindale Electric Corp.
130 North Main Street, Lisbon, NH 03585
Phone: 603-838-6624 Fax: 603-838-6160
 

 

Mediation


Da Ihre Firma sehr preisbewusst ist, beabsichtigt Ihr Chef, ausländische Arbeitskräfte einzustellen. Sie werden daher gebeten auf der 1. Versammlung mit den neuen Mitarbeitern den wesentlichen Inhalt des Zeitungsartikels wiederzugeben. (8 Fakten)
 

Alte Stromleitungen, Steckdosen oder Lichtschalter werden zu schnell eine Gefahr für Leib und Leben. Isolationsfehler an Kabeln beispielsweise können Brände auslösen oder zu schweren Verletzungen durch elektrische Schläge führen.
Um diesen Gefährdungen vorzubeugen, raten die meisten Elektriker dazu, den Zustand ihrer Elektroinstallationen überprüfen zu lassen.
Entspricht sie dem aktuellen Stand? Sind genügend Steckdosen vorhanden? Gibt es Leitungen, die nachträglich installiert wurden? Sprechen öfter die Sicherungen an, wenn viele Geräte im Einsatz sind? Alles Dinge, die ein Elektriker kontrollieren und anhand derer er feststellen kann, ob die Elektroinstallation ausgetauscht werden muß.
Doch für alle sicherheitsrelevanten Modernisierungsarbeiten gilt: Finger weg von elektrischen Stromkreisen. Die gehören ausschließlich in die Hände des Fachmanns.